Intelli-Tank Manual (106759)092204 – 1 – Class 1
Intelli-Tank
Water/foam tank level display
with Drip Empty
Contents …………………………………………………. 1
Overview …………………………………………………. 2
Operation …………………………………………………. 3
Installation …………………………………………………. 5
Wiring …………………………………………………. 7
Calibration …………………………………………………. 9
Dim function …………………………………………………. 12
Self test …………………………………………………. 12
Passwords …………………………………………………. 13
Troubleshooting
…………………………………………………. 14
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Intelli-Tank

Intelli-Tank Manual (106759)092204 – 1 – Class 1 Intelli-Tank Water/foam tank level display with ‘Drip’ Empty Contents …………………………………………………. 1

Strona 2

Intelli-Tank Manual (106759)092204 – 10 – Class 1 2 Point Calibration 1. Enter the password RLLR LLRL. The unit will respond by flashing the two c

Strona 3

Intelli-Tank Manual (106759)092204 – 11 – Class 1 6. Fill the tank to the one-half point and then activate the RIGHT switch. The unit will flash th

Strona 4 - Miscellaneous indications:

Intelli-Tank Manual (106759)092204 – 12 – Class 1 Dimming the Display The display can be dimmed by applying VIGN to pin 3 (Dim Display input). To

Strona 5

Intelli-Tank Manual (106759)092204 – 13 – Class 1 RLLR LLRL 2 point calibration RLLR LRLR 5 point calibration RLLR RLLR 9 point calibration RLL

Strona 6 - – 6 – Class 1

Intelli-Tank Manual (106759)092204 – 14 – Class 1 Condition Evaluate Bottom two LEDs alternate flashing. Unit fails self test, LED 1 flashing. Che

Strona 7 - – 7 – Class 1

Intelli-Tank Manual (106759)092204 – 15 – Class 1 Condition Evaluate The bottom two LEDs are on and occasionally they go out and the top two flash

Strona 8 - Typical installation layout

Intelli-Tank Manual (106759)092204 – 16 – Class 1

Strona 9

Intelli-Tank Manual (106759)092204 – 2 – Class 1 The Intelli-Tank 4 light tank level is designed to display a liquid’s volume to an eighth of a ta

Strona 10

Intelli-Tank Manual (106759)092204 – 3 – Class 1 When the unit is first powered up the LEDs will cycle on individually starting with the bottom L

Strona 11

Intelli-Tank Manual (106759)092204 – 4 – Class 1 Miscellaneous indications: Condition LED 4 LED 3 LED 2 LED 1 Invalid calibration AlternaFLAS

Strona 12

Intelli-Tank Manual (106759)092204 – 5 – Class 1 Intelli-Tank display The display requires a cutout as shown. The unit is water tight and may be

Strona 13

Intelli-Tank Manual (106759)092204 – 6 – Class 1 Pressure Transducer The transducer has a ¼” NPT mount and must be mounted vertically as depic

Strona 14

Intelli-Tank Manual (106759)092204 – 7 – Class 1 Power and Ground It is imperative that a system utilizing Master and Remote tank level units conn

Strona 15

Intelli-Tank Manual (106759)092204 – 8 – Class 1 Typical installation layout.

Strona 16

Intelli-Tank Manual (106759)092204 – 9 – Class 1 The Intelli-Tank display can be calibrated three different ways: 2-point (level calibration), 5-